+ Wiring connections : 1P 2W, 1P 3W, 3P 3W, 3P 4W
+ Voltage : 150 / 300 / 600 /1000V
+ Current : Max 3000A
+ Frequency meter range 40~70Hz
Detail
• |
Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured. |
• |
12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis. |
• |
One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory. |
• |
Direct communication with PC via USB cable |
|
|
• |
Built-in Input / Output Function of external signal enables the signal transmission to alarms. |
• |
2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function. |
• |
Pull / Insert of CF card possible whenever on recording under the function of memory backup device. |
• |
Can monitor insulation at leakage current by using optional leak clamp sensors. |
• |
Built-in Print Screen Function enables to record display screen (Records 512 screens by using CF card: 1 screen 40KB). |
• |
Can display Waveform and Vector, and can confirm the wiring connection, too. |
• |
Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V. |
 |
* Attention for KEW6310 customers: |
|
Flicker measurements are possible with firmware of KEW6310 upgrade (Ver.2.01), PC software PQA Master upgrade (Ver. 2.01) and an optional accessory Flicker sensor KEW8325F. |
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Wiring connections |
 |
 |
 |
1P 2W, 1P 3W, 3P 3W, 3P 4W |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measurements and parameters |
 |
 |
 |
Voltage, Current, Frequency, Active power, Reactive power, Apparent power, Active energy, Reactive energy, Apparent energy, Power factor (cos θ), Neutral current, Demand, Harmonics, Quality (Swell/Dip/Instantaneous Stop, Transients/Over Voltage, Inrush Current, Unbalance Rate, IEC Flicker [Pst(1 min)*, Pst, Plt]), Phase Advance Condenser (*Pst can be shown in details for 1 minute intervals.) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Other functions |
 |
 |
 |
Digital output function, External communication function, Scaling function |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Voltage : |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Ranges [RMS] |
 |
 |
 |
150 / 300 / 600 /1000V (CF: 2.5 or less, 100% or less of each range) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Allowable input |
 |
 |
 |
10~110% of each range (1000V range : 20%~) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Display ranges |
 |
 |
 |
5~120% of each range |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accuracy |
 |
 |
 |
|±0.3%rdg±0.2%f.s. (sine wave, 45~65Hz) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Current : |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Ranges [RMS] |
 |
 |
 |
8128 ( |
50A |
type ) |
: |
1 / 5 / 10 / 20 / 50A |
8127 ( |
100A |
type ) |
: |
10 / 20 / 50 / 100A |
8126 ( |
200A |
type ) |
: |
20 / 50 / 100 / 200A |
8125 ( |
500A |
type ) |
: |
50 / 100 / 200 / 500A |
8124 ( |
1000A |
type ) |
: |
100 / 200 / 500 / 1000A |
8129 ( |
3000A |
type ) |
: |
300 / 1000 / 3000A |
(CF:3.0 or less. 90% or less of each range) |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Allowable input |
<img wid |
|
|