AC A (50/60Hz) |
200mA/2/20/200/1000A |±2.5%rdg±5dgt (200mA/2/20A) |±3.0%rdg±5dgt (200A, 0~500A) |±5.5%rdg (501~1000A) |
AC A (WIDE) |
200mA/2/20/200/1000A |±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A) |±2.0%rdg±5dgt (50/60Hz) (200A, 0~500A) |±5.0%rdg (50/60Hz) (501~1000A) |
Conductor Size |
Ø68mm max. |
Frequency Response |
40Hz~1kHz |
Output |
Waveform : |
AC200mV against the maximum value of each range (1000A range is 100mV) |
Recorder : |
DC200mV against the maximum value of each range (1000A range is 100mV) |
|
Crest Factor |
3.0 or less |
Withstand Voltage |
3700V AC for 1 minute |
Applicable Standard |
IEC 61010-1 CAT.III 300V Pollution degree 2 IEC 61010-2-032 |
Power Source |
6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours |
Dimensions |
250(L) × 130(W) × 50(D)mm |
Weight |
Approx. 570g (including battery) |
Accessories |
9094 (Carrying Case) 6F22 × 1 Instruction Manual |
Optional |
7073 (2WAY Output Cord) |