For full functionality of this site it is necessary to enable JavaScript.

KYORITSU 1061 Digital Multimeter


ModeTrue RMS
DC V50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V
V AC [RMS] 50.000/500.00mV/5.0000/50.000/500.00/1000.0V
DCV + ACV5.0000/50.000/500.00/1000.0V
DC A: 500.00/5000.0μA/50.000/500.00mA/5.0000/10.000A
AC A [RMS]: 500.00/5000.0μA/50.000/500.00mA/5.0000/10.000A
DCA + ACA500.00/5000.0μA/50.000/500.00mA/5.0000/10.000A
Ω500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ
Continuity buzzer500.0Ω
Diode test: 2.4V
C5.000/50.00/500.0nF/5.000/50.00/500.0μF/5.000/50.00mF
F: 2,000 ~ ~ 99.99/90.0 9.999/9.00 9.999/9.00 ~ ~ ~ 999.9Hz/0.900 99.99kHz
Temperature: -200 ~ 1372 º C (K-type)
Other FeaturesData Hold (/ H), Auto Hold (A / H), Peak Hold * (/ H), Range Hold (/ H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (capacitor, Resistance)Relative values, Save to MemoryLCD backlight
SourceR6P (1.5V) × 4
Size: 192 (L) × 90 (W) × 49 (D) mm
Weight: 560g
SourceLR44 (1.5V) × 2
Size: 192 (L) × 90 (W) × 49 (D) mm
Weight: 560g
Accessories: CaseBatteryManuals


Details
 

High Accuracy, High Performance and Reliable Measurements
0.02% basic DC accuracy
Large display with 50,000 counts
Dual display for double indication for AC and DC, V and Hz, etc.
True-RMS Measurements AC and AC+DC
Wide AC Frequency bandwidth from 10Hz to 100kHz *
True-RMS or MEAN value detection mode can be selected *
Fast Peak Hold response time of 250µs
Low-pass filter for motor drive measurements *
Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current *
User calibration function
* Only for KEW 1062

1061/1062
CE
(Photo: 1062)
Safety design for industrial use
Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V
Terminal shutter to prevent incorrect test leads is insertion in current terminals
Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
Large data internal memory
  KEW 1062: 10,000 data (logging), 100 data (manual)
  KEW 1061: 1,000 data (logging), 100 data (manual)
Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)

TRUE RMS CAT.IV 600V
 
<td colspan="3" bgcolor="#fff
KEW 1061 KEW 1062
Detection mode RMS MEAN/RMS (switch)
DC V 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V
(Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V])

|±0.02%rdg±2dgt (Basic accuracy)
AC V
[RMS]
50.000/500.00mV/5.0000/50.000/500.00/1000.0V
(Input impedance: 11MΩ<50pf 50="" 500mv="" 5v="" 10m="" 50pf="" 50="" 500="" 1000v="" span="">
|±0.7%rdg±30dgt (Basic accuracy) |±0.4%rdg±30dgt (Basic accuracy)
AC V
[MEAN] *
-- 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V
(Input impedance:
11MΩ<50pf 50="" 500mv="" 5v="" br=""> 10MΩ<50pf 50="" 500="" 1000v="" span="">

|±1%rdg±30dgt (Basic accuracy)
DCV+ACV 5.0000/50.000/500.00/1000.0V
(Input impedance: 11MΩ<50pf 5v="" 10m="" 50pf="" 50="" 500="" 1000v="" span="">
|±1%rdg±10dgt (Basic accuracy) |±0.5%rdg±10dgt (Basic accuracy)
DC A 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A

|±0.2%rdg±5dgt (Basic accuracy)
AC A
[RMS]
500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
|±1%rdg±20dgt (Basic accuracy) |±0.75%rdg±20dgt
|(Basic accuracy)
AC A
[MEAN] *
-- 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A

|±1.5%rdg±20dgt (Basic accuracy)
DCA+ACA 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
  • 良質な取り決め
  • オリジナル保証
  • 宅配便
  • 買い取り簡単化

おまけチャンス‐ニュースを受ける登録