DCV: 600.0mV/6.000/60.00/600.0/1000V
ACV[RMS]: 600.0mV/6.000/60.00/600.0/1000V
DCA: 600.0/6000μA/60.00/440.0mA/6.000/10.00A
ACA [RMS]: 600.0/6000μA/60.00/440.0mA/6.000/10.00A
Ω: 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
Continuously monitored: 600.0Ω
Checkdiode: 2V
C: 10.00/100.0nF/1.000/10.00/100.0/1000μF
F: 10.00~~9.999/9.00999.9Hz/0.90099.99/90.0~~99.99kHz
Temperature: -50~ 600ºC(withK-typeTemperatureprobe)
Other Features: DataHold (D/H),AutoHold(A /H), RangeHold (R/H)...
Source: R6P(1.5V)× 4
Size: 192 (L)×90 (W)×49 (D)mm
Weight: 560g
Accessories: Battery,probe,Manuals
 Details
| 
| 
| High Accuracy, High Performance and Reliable Measurements |  
| • | 0.09% basic DC accuracy |  
| • | Large display with 6,000 counts |  
| • | True-RMS Measurements |  
| • | True-RMS or MEAN value detection mode can be selected * |  
| • | Low-pass filter for motor drive measurements |  
| • | User calibration function |  
|  |  
| Safety design for industrial use |  
| • | Complies with IEC 61010-1 CAT.IV 600V, CAT.III 1000V
 |  
| • | Terminal shutter to prevent incorrect insertion of test leads in current terminals |  
| • | Very wide operating temperature range from -10 to 55ºC
 |  |  
  
  (Photo: 1052)
 |  
|  |  
| Reliable support for data management * |  
| • | Large data internal memory * |  
|  |  | KEW 1052: 1,600 data (logging), 100 data (manual) |  
| • | Download data and Live Monitoring on a PC via the USB interface (Option for USB Communication set) *
 |  
|  |  
| * Only for KEW 1052 |  
 | 
|  | 
| 
| 
|  |  |  |  |  |  |  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  | KEW 1051 |  |  |  | KEW 1052 |  |  |  
|  |  |  |  |  |  |  |  
|  |  
|  |  |  |  |  |  |  |  
|  |  | Detection mode |  |  |  | RMS |  |  |  | MEAN/RMS (switch) |  |  |  
|  |  |  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | DC V |  |  |  | 600.0mV/6.000/60.00/600.0/1000V (Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
 
  |±0.09%rdg±2dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | AC V [RMS] |  |  |  | 600.0mV/6.000/60.00/600.0/1000V (Input impedance: 10MΩ<200pf 600mv="" 11m="" 50pf="" 6v="" br=""> 10MΩ<50pf 60="" 600="" 1000v="" span="">
 
  |±0.5%rdg±5dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | DC A |  |  |  | 600.0/6000µA/60.00/440.0mA/6.000/10.00A 
  |±0.2%rdg±2dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | AC A [RMS] |  |  |  | 600.0/6000µA/60.00/440.0mA/6.000/10.00A 
  |±0.75%rdg±5dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Ω |  |  |  | 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ 
  |±0.4%rdg±1dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Continuity buzzer |  |  |  | 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω) |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Diode test |  |  |  | 2.000V  |±1%rdg±2dgt Open curcuit voltage: <3.5v approx="" 0="" 5ma="" measuring="" current="" td="">
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Capacitance |  |  |  | 10.00/100.0nF/1.000/10.00/100.0/1000µF 
  |±2%rdg±5dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Frequency |  |  |  | 10.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz 
  |±0.02%rdg±1dgt (Basic accuracy)
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Temperature |  |  |  | -50~600ºC  |±2%rdg±2ºC (with the use of K-type Temperature probe) |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Other functions |  |  |  | Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H), Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory  *,
 LCD backlight
 |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Withstand voltage |  |  |  | 6,880V/5 sec. |  |  |  
|  |  |  |  |  |  
|  |  
|  |  |  |  |  |  
|  |  | Applicable standards
 |  |  |  | IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC)
 |  |  |  
|  |  |  |  |  |  
|  |  |  |